This report measures how long and how often US electricity customers lose power, by state and year, using the reliability data utilities file with the US Energy Information Administration on Form EIA-861. It uses the two standard industry measures: SAIDI, the total minutes without power per customer per year, and SAIFI, the number of interruptions per customer. Both are reported with and without “major event days”, the storm days that dominate outage totals. Outages matter for heating and cooling: a heat pump or furnace blower stops with the grid, and generators used during outages are the leading product in carbon monoxide deaths (see carbon monoxide death statistics).
Last reviewed: November 2026 · By the HVAC Brief Editorial Team · Our sourcing and editorial standards
In 2024 the average customer of reporting utilities was without power for 11.0 hours, the most in the twelve years of data and nearly three times the 3.8 hours recorded in 2013. Almost all of the increase came from major events.
Executive summary
Utilities reporting to the IEEE standard served 130 million customers in 2024, about 79 percent of all US electricity customers. Their customer-weighted average outage duration was 663 minutes (11.0 hours) in 2024, with 1.52 interruptions per customer. That is the highest duration in the 2013 to 2024 series, ahead of 2017 (8.4 hours), 2021 (7.9 hours) and 2020 (7.6 hours), all hurricane and winter-storm years.
Excluding major event days, outage time has barely moved: 1.8 hours in 2013 and 2.2 hours in 2024. Routine reliability, from equipment failures, animals and minor weather, is flat. The growth is entirely in major events, which accounted for 80 percent of 2024 outage minutes against 51 percent in 2013.
South Carolina had the longest average outage time in 2024, 52.6 hours per customer, after Hurricane Helene, followed by Maine (29.1 hours), Texas (26.9 hours) and North Carolina (25.3 hours). Over 2020 to 2024, Louisiana averaged 39.4 hours a year, the most of any state, driven by Hurricanes Laura and Ida.
Cooperative utility customers, mostly rural, averaged 2.0 interruptions in 2024 against 1.5 for investor-owned utility customers and 1.1 for municipal utilities, and municipal customers lost power for the shortest time (2.7 hours).
Key findings
- Average US outage time per customer, 2024: 11.0 hours (663 minutes), the highest since at least 2013 (EIA-861, HVAC Brief calculation).
- 2013: 3.8 hours. 2013 to 2017 average: 4.8 hours; 2020 to 2024 average: 7.6 hours.
- Outage time excluding major event days: 2.2 hours in 2024, essentially unchanged since 2013 (1.8 hours).
- Major event days: 80 percent of all 2024 outage minutes.
- Interruptions per customer, 2024: 1.52, up from 1.17 in 2013.
- Worst state 2024: South Carolina, 52.6 hours per customer.
- Most reliable state 2024 (of those with 50%+ coverage): District of Columbia, 33 minutes.
- Highest five-year average, 2020 to 2024: Louisiana, 39.4 hours a year.
- Worst state-year in the data: Louisiana 2021, 97.8 hours per customer.
- Cooperative customers: 2.0 interruptions a year; investor-owned: 1.5; municipal: 1.1.
- Data covers about 79 percent of US electricity customers; six states with under 50 percent coverage are excluded from rankings.
How outage time is measured
SAIDI (System Average Interruption Duration Index) is total customer-minutes of sustained interruptions divided by customers served: the average time each customer was without power in a year. SAIFI (System Average Interruption Frequency Index) is the average number of sustained interruptions per customer. Under the IEEE 1366 standard, sustained means longer than five minutes, and a “major event day” is a day whose outage total is statistically far above the utility’s norm, typically a hurricane, ice storm or derecho. Utilities report both measures to EIA with and without major event days. National and state figures here are customer-weighted averages across reporting utilities, which is how EIA itself summarises the data.
US power outage trend, 2013 to 2024
| Year | Minutes (all events) | Hours | Minutes (excl. major events) | Interruptions | Major event share | Customers covered |
|---|---|---|---|---|---|---|
| 2013 | 227 | 3.8 | 111 | 1.17 | 51% | 96M |
| 2014 | 236 | 3.9 | 113 | 1.24 | 52% | 109M |
| 2015 | 209 | 3.5 | 117 | 1.26 | 44% | 114M |
| 2016 | 268 | 4.5 | 120 | 1.31 | 55% | 116M |
| 2017 | 506 | 8.4 | 117 | 1.41 | 77% | 118M |
| 2018 | 349 | 5.8 | 121 | 1.33 | 65% | 117M |
| 2019 | 296 | 4.9 | 123 | 1.32 | 59% | 120M |
| 2020 | 456 | 7.6 | 116 | 1.37 | 75% | 121M |
| 2021 | 471 | 7.9 | 126 | 1.41 | 73% | 123M |
| 2022 | 333 | 5.6 | 131 | 1.41 | 61% | 125M |
| 2023 | 367 | 6.1 | 124 | 1.34 | 66% | 127M |
| 2024 | 663 | 11.0 | 132 | 1.52 | 80% | 130M |
Source: EIA Form EIA-861 reliability data, IEEE standard, customer-weighted. HVAC Brief calculation.
The year-to-year swings follow the weather. 2017 (Hurricanes Harvey and Irma), 2020 (Laura, Isaias, western wildfire shutoffs), 2021 (Ida and the February Texas freeze) and 2024 (Beryl, Helene and Milton) are the peaks. The line excluding major events is nearly flat at about two hours, which is why utilities often describe reliability as stable while customers experience more and longer blackouts. A long winter blackout turns that trend into a heating problem, and keeping a house warm during a power outage sorts the heat sources that work without electricity from the ones that kill.
Power outages by state, 2024
States are ranked by total outage minutes per customer in 2024. The coverage column shows the share of the state’s electricity customers served by utilities reporting under the IEEE standard. Alabama, Hawaii, New York, Oklahoma, Virginia, Vermont are excluded because coverage was under 50 percent.
| Rank | State | Minutes (all events) | Hours | Minutes (excl. major events) | Interruptions | Coverage |
|---|---|---|---|---|---|---|
| 1 | South Carolina | 3,155 | 52.6 | 116 | 2.20 | 93% |
| 2 | Maine | 1,749 | 29.1 | 274 | 3.64 | 100% |
| 3 | Texas | 1,614 | 26.9 | 153 | 2.21 | 65% |
| 4 | North Carolina | 1,518 | 25.3 | 144 | 1.82 | 91% |
| 5 | Florida | 1,488 | 24.8 | 67 | 1.78 | 84% |
| 6 | Georgia | 1,208 | 20.1 | 211 | 2.09 | 87% |
| 7 | West Virginia | 1,166 | 19.4 | 486 | 2.83 | 97% |
| 8 | New Hampshire | 735 | 12.3 | 84 | 1.62 | 88% |
| 9 | Nebraska | 698 | 11.6 | 70 | 1.24 | 66% |
| 10 | Washington | 644 | 10.7 | 157 | 1.77 | 90% |
| 11 | Louisiana | 631 | 10.5 | 216 | 2.36 | 72% |
| 12 | Mississippi | 607 | 10.1 | 279 | 2.17 | 69% |
| 13 | Oregon | 579 | 9.7 | 124 | 1.32 | 88% |
| 14 | Kentucky | 538 | 9.0 | 146 | 1.78 | 94% |
| 15 | Arkansas | 528 | 8.8 | 202 | 2.14 | 82% |
| 16 | Ohio | 511 | 8.5 | 133 | 1.29 | 96% |
| 17 | Michigan | 482 | 8.0 | 161 | 1.36 | 94% |
| 18 | Pennsylvania | 353 | 5.9 | 132 | 1.39 | 84% |
| 19 | Montana | 342 | 5.7 | 152 | 1.63 | 72% |
| 20 | Alaska | 323 | 5.4 | 192 | 2.32 | 80% |
| 21 | Indiana | 310 | 5.2 | 123 | 1.27 | 84% |
| 22 | Wisconsin | 297 | 4.9 | 98 | 1.04 | 74% |
| 23 | Kansas | 290 | 4.8 | 104 | 1.44 | 80% |
| 24 | Tennessee | 289 | 4.8 | 170 | 1.94 | 74% |
| 25 | California | 285 | 4.8 | 165 | 1.35 | 94% |
| 26 | New Mexico | 273 | 4.5 | 152 | 1.33 | 85% |
| 27 | Colorado | 257 | 4.3 | 119 | 1.39 | 92% |
| 28 | Minnesota | 222 | 3.7 | 91 | 1.26 | 87% |
| 29 | Missouri | 213 | 3.5 | 107 | 1.16 | 83% |
| 30 | Idaho | 204 | 3.4 | 152 | 1.31 | 93% |
| 31 | Iowa | 200 | 3.3 | 84 | 1.21 | 53% |
| 32 | New Jersey | 173 | 2.9 | 99 | 1.12 | 99% |
| 33 | Nevada | 159 | 2.6 | 64 | 1.11 | 100% |
| 34 | Illinois | 158 | 2.6 | 59 | 0.85 | 97% |
| 35 | Connecticut | 153 | 2.5 | 74 | 0.88 | 100% |
| 36 | Wyoming | 138 | 2.3 | 116 | 0.94 | 71% |
| 37 | Maryland | 118 | 2.0 | 75 | 0.82 | 99% |
| 38 | Delaware | 118 | 2.0 | 67 | 0.85 | 88% |
| 39 | Utah | 115 | 1.9 | 105 | 0.96 | 85% |
| 40 | Rhode Island | 104 | 1.7 | 61 | 0.90 | 98% |
| 41 | Massachusetts | 104 | 1.7 | 77 | 0.85 | 90% |
| 42 | North Dakota | 103 | 1.7 | 87 | 0.94 | 84% |
| 43 | South Dakota | 86 | 1.4 | 62 | 0.82 | 71% |
| 44 | Arizona | 84 | 1.4 | 70 | 0.95 | 96% |
| 45 | District of Columbia | 33 | 0.5 | 26 | 0.27 | 99% |
Source: EIA-861 2024. HVAC Brief calculation.
The worst states in 2024 sit in the paths of that year’s hurricanes, Helene in the Southeast and Beryl in Texas, plus Maine, which ranks near the top in most years. The most reliable states, District of Columbia, Arizona, South Dakota, North Dakota, Massachusetts, all came in under two hours.
Five-year averages by state
A single year depends on where the storms landed. The 2020 to 2024 average gives a steadier picture of which states lose power most.
| State | Hours a year (all events) | Minutes a year (excl. major events) | Interruptions a year |
|---|---|---|---|
| Louisiana | 39.4 | 230 | 2.58 |
| Maine | 22.1 | 241 | 3.26 |
| Mississippi | 15.8 | 243 | 2.07 |
| West Virginia | 15.5 | 467 | 2.55 |
| Texas | 14.1 | 153 | 2.03 |
| South Carolina | 13.6 | 116 | 1.56 |
| Connecticut | 12.5 | 74 | 1.13 |
| Michigan | 11.5 | 168 | 1.45 |
| Arkansas | 9.9 | 224 | 1.99 |
| Florida | 9.8 | 69 | 1.25 |
| Oregon | 9.8 | 113 | 1.24 |
| North Carolina | 9.7 | 145 | 1.65 |
| Kentucky | 9.1 | 139 | 1.65 |
| Tennessee | 8.6 | 171 | 2.38 |
| Alaska | 8.4 | 266 | 2.98 |
Louisiana stands far above every other state, averaging 39.4 hours a year. Maine, Mississippi and West Virginia follow; West Virginia’s figure is high even without major events (467 minutes), consistent with a rugged, heavily forested rural service territory.
The worst outage years on record
| State | Year | Hours per customer | Interruptions |
|---|---|---|---|
| Louisiana | 2021 | 98 | 3.3 |
| Louisiana | 2020 | 72 | 3.3 |
| South Carolina | 2024 | 53 | 2.2 |
| Connecticut | 2020 | 51 | 2.0 |
| Florida | 2017 | 45 | 2.1 |
| Maine | 2017 | 42 | 2.8 |
| North Carolina | 2018 | 31 | 2.3 |
| Maine | 2023 | 31 | 3.3 |
| Maine | 2024 | 29 | 3.6 |
| Maine | 2020 | 29 | 3.9 |
Outages by type of utility
| Ownership | Customers | Hours (all events) | Minutes (excl. major events) | Interruptions |
|---|---|---|---|---|
| Investor Owned | 100.1M | 12.0 | 128 | 1.49 |
| Cooperative | 16.1M | 11.5 | 188 | 2.02 |
| Municipal | 10.4M | 2.7 | 90 | 1.07 |
| Political Subdivision | 3.1M | 5.5 | 90 | 1.33 |
| State | 0.2M | 1.1 | 54 | 0.72 |
Cooperatives typically serve rural areas with long distribution lines and few customers per mile, so each storm reaches more of their customers. Investor-owned utility customers had the longest average total outage time in 2024 because the year’s hurricanes hit large investor-owned systems in Florida, the Carolinas and Texas.
Outages by region
| Region | 2024 | 2020 to 2024 average | 2013 to 2017 average | 2024 excl. major events (min) |
|---|---|---|---|---|
| South | 20.6 | 11.5 | 6.7 | 148 |
| Northeast | 5.7 | 6.4 | 4.3 | 114 |
| Midwest | 5.5 | 5.5 | 4.3 | 108 |
| West | 5.0 | 4.6 | 2.6 | 140 |
The South, home to the Gulf and Atlantic hurricane coasts, has the longest outages in both periods and the largest increase. Major events in the Northeast are typically nor’easters and ice storms, and in the West windstorms and wildfire-related shutoffs. Regional figures include all IEEE-reporting utilities, including those in the six low-coverage states. Routine outage time excluding major events is similar across regions, between one and a half and three hours.
Original synthesis (HVAC Brief calculations)
1. Outages are getting longer, and storms explain all of it
Average outage time rose from 4.8 hours a year in 2013 to 2017 to 7.6 hours in 2020 to 2024, a 58 percent increase. Outage time excluding major event days averaged 115 minutes in the first period and 126 in the second. In other words, the grid’s everyday performance is unchanged, and the entire increase is in large events. Planning for heating and cooling resilience is therefore planning for multi-day storm outages, not for frequent short ones.
2. What an outage means for heating and cooling
Every central system that moves air needs electricity, including gas furnaces, whose blowers and igniters run on household current. In 2024 the average reporting customer spent 11.0 hours without power, and in South Carolina more than two days. Heat pumps lose both heating and cooling. Our guides to AC problems after an outage and furnaces after an outage cover restarting equipment; the risk to life is mostly from portable generators, linked to about 98 carbon monoxide deaths a year (CPSC).
3. Measured reliability depends on who reports
EIA’s data cover about 79 percent of customers under the IEEE standard. Coverage is under 50 percent in Alabama, Hawaii, New York, Oklahoma, Virginia, Vermont, so no reliable state figure can be built from the public file for those states. Some utilities report under their own standards instead, which EIA records separately and which are not comparable. Rankings that include every state without noting coverage overstate their precision.
Charts worth building from this data
- Stacked bar of outage minutes per customer, major events vs routine, 2013 to 2024.
- Choropleth of 2024 outage hours per customer by state.
- Small multiples of state outage hours by year, Gulf and Atlantic states.
- Dot plot of five-year average outage hours by state.
- Bar chart of interruptions by utility ownership type.
Most quotable statistics
- The average US electricity customer was without power for 11.0 hours in 2024, the most since at least 2013 (EIA data, HVAC Brief analysis).
- Excluding major storms, average outage time has stayed near two hours a year since 2013; all of the increase is from major events.
- South Carolina customers averaged 52.6 hours without power in 2024.
- Louisiana customers averaged 39.4 hours without power a year from 2020 to 2024, the most of any state.
- Major event days accounted for 80 percent of 2024 outage minutes.
- Rural cooperative customers averaged 2.0 power interruptions in 2024.
Data limitations
- Figures cover utilities reporting under the IEEE 1366 standard, about 79 percent of customers nationally; coverage varies by state and is shown.
- Customer-weighted averages across utilities can be moved by one large utility’s year.
- Utilities define major event days using their own historical data, so the split between major and routine events is consistent within a utility but not identical across utilities.
- Momentary interruptions under five minutes are excluded.
- State values assign each utility’s reported figure to the state on its reliability record; multi-state utilities may report separately by state or as a system.
- 2024 is the latest EIA-861 final data year at the time of writing.
Downloadable dataset: recommended fields
| Field | Description |
|---|---|
| year | Data year |
| state | State |
| utility_id | EIA utility number |
| ownership | Utility ownership type |
| saidi_all | Minutes per customer, all events |
| saidi_excl_med | Minutes per customer, excluding major event days |
| saifi_all | Interruptions per customer |
| customers | Customers in reliability report |
| coverage | Share of state customers covered |
Press summary
The average US electricity customer went 11.0 hours without power in 2024, the most in at least twelve years and nearly three times the 2013 level, according to an HVAC Brief analysis of Energy Information Administration data. Routine outages have not increased; major storms account for the entire rise. South Carolina customers averaged 52.6 hours without power after Hurricane Helene, and Louisiana has the worst five-year record.
Suggested headlines
- Americans spent 11.0 hours without power in 2024, a record
- The grid isn’t failing more often, storms are just getting bigger
- South Carolina lost more power than any state in 2024
- Louisiana has the worst power reliability in the US
- Rural co-op customers lose power most often
Source quality ranking
| Source | Tier | Why |
|---|---|---|
| EIA Form EIA-861 reliability data, 2013 to 2024 | Tier 1 | Mandatory federal utility survey; IEEE 1366 metrics |
| EIA-861 sales to ultimate customers | Tier 1 | Customer counts for coverage |
| Outage-tracking websites | Excluded | Real-time scrapes; not comparable across years |
Methodology
- Source: EIA-861 annual files 2013 to 2024 (Reliability_YYYY.xlsx), IEEE standard columns: SAIDI and SAIFI with major event days, SAIDI without major event days, number of customers.
- National and state values are customer-weighted means across utilities reporting a SAIDI value and a positive customer count; values above 20,000 minutes are treated as errors and excluded (none affected published rankings).
- Coverage = customers in reliability reports / total ultimate customers (bundled and delivery service) in the 2024 EIA-861 sales file, capped at 100 percent where reporting differences push the ratio slightly above it (Nevada). States under 50 percent are excluded from rankings.
- Major event share = 1 minus SAIDI excluding major events / SAIDI including them.
- Five-year averages are the mean of each state’s annual customer-weighted values for 2020 to 2024.
Frequently asked questions
How many hours do Americans lose power each year?
In 2024 the average customer of reporting utilities was without power for 11.0 hours. Excluding major storms, the average is about two hours a year.
Which state has the most power outages?
In 2024, South Carolina (52.6 hours per customer). Over 2020 to 2024, Louisiana had the highest average, 39.4 hours a year.
Which state has the most reliable electricity?
Among states with good data coverage, District of Columbia, Arizona and South Dakota had the shortest outage times in 2024, under two hours per customer.
Are power outages getting worse in the US?
Yes in total: the 2020 to 2024 average (7.6 hours) is 58 percent above 2013 to 2017 (4.8 hours). But outages excluding major storms are flat, so the increase comes from major weather events.
What is SAIDI?
The System Average Interruption Duration Index: the average total minutes each customer was without power over a year, counting interruptions longer than five minutes.
What is a major event day?
A day when a utility’s outage total is statistically far above its normal range under the IEEE 1366 method, usually because of a hurricane, ice storm or other severe weather.
How often does the average customer lose power?
1.52 times in 2024, counting interruptions over five minutes.
Do rural areas lose power more?
Cooperative utilities, which mostly serve rural areas, averaged 2.0 interruptions per customer in 2024 against 1.5 for investor-owned utilities.
Does a gas furnace work in a power outage?
Usually not. Modern gas furnaces need electricity for the blower, igniter and controls. Only some gravity or wall heaters run without power.
Is it safe to run a generator during an outage?
Only outdoors and away from openings. Portable generators are linked to about 98 carbon monoxide deaths a year, the largest single product category in CPSC data.
Cite this report
Sources
- US Energy Information Administration, Form EIA-861 Annual Electric Power Industry Report, reliability and sales files, 2013 to 2024.
- IEEE 1366, Guide for Electric Power Distribution Reliability Indices.
- CPSC, Non-Fire Carbon Monoxide Deaths, 2022 Annual Estimates.
The HVAC Brief is an independent trade publication. We do not sell equipment, take manufacturer advertising, or accept payment for placement in our research. Corrections welcome.

Leave a Reply