To stop drafts from windows, first find where the air moves: seal the trim to wall joint with caulk, the sliding sash channels with V-strip or pile weatherstrip, and the meeting rail by locking it tight. If the glass itself feels cold and no smoke moves, it is falling air, so add a shade, film or storm panel.
Where is the cold air getting in: trim, sash channel, meeting rail or glass?
A window has five places that feel drafty, and only four are leaks. DOE’s rule splits the fixes: caulk is for cracks under 1/4 inch between parts that do not move, and weatherstripping is for parts that do (DOE, Caulking).
To tell them apart, use DOE’s pressurization test: on a cold, windy day, turn off gas furnaces and water heaters, shut windows and doors, run the bath fans, range hood and dryer, and pass a lit incense stick along each joint. Where the smoke wavers, air is moving (DOE, Detecting Air Leaks). Burners go off first: the fans can pull flue gas indoors. DOE’s quicker checks: a sash that rattles leaks, and a dollar bill that slides out of a closed sash without dragging means the seal is not touching.
| Where you feel it | Confirm with | Matching fix (DOE material) | Renter OK? |
|---|---|---|---|
| Trim to wall joint | Smoke at the trim edge | Caulk, gaps under 1/4 in, above 45°F | Rope caulk only |
| Sash side channels | Rattle, loose dollar bill | V-strip tension seal (“very effective”); fin seal pile on aluminum sliders (“very durable”) | Self-stick vinyl, usually |
| Meeting rail | Smoke at the rail, lock does not pull tight | Close the lock, then V-strip | Lock yes; ask before strip |
| Top and bottom rails | Light under the sash at night | Foam or EPDM tape, which “works well when compressed” | Yes |
| The glass itself | No smoke movement, glass cold to the hand | Not a leak: cellular shade, film kit or storm panel | Yes |
Why does the window feel drafty when the smoke does not move?
Because cold glass pulls heat from you by radiation and chills the air touching it, which sinks; caulk fixes neither. Lawrence Berkeley National Laboratory modeled glazings at 0°F outside and 70°F inside and concluded that “people often mistake long-wave heat loss to a cold window for a draft” (LBNL-44032). The same paper puts the falling air at about 0.25 m/s for a seat 3.3 ft from a 10 by 9 ft window, and calls draft effects “typically small” for residential-size windows.
| Glazing (LBNL code) | U-factor, Btu/ft²·h·°F | Inside glass surface | Colder than room air by |
|---|---|---|---|
| Single clear (S Cl) | 1.11 | 16.9°F | 53.1°F |
| Double clear, air gap (D Cl) | 0.49 | 45.3°F | 24.7°F |
| Double low-E, argon (D LE1Ar) | 0.30 | 54.3°F | 15.7°F |
| Double selective low-E, argon (D SSLEAr) | 0.24 | 57.2°F | 12.8°F |
| Triple low-E, krypton (T LEKr) | 0.11 | 63.7°F | 6.3°F |
A single pane at 16.9°F needs a second layer between it and the room. DOE says tightly installed cellular shades cut heat loss through the window by 40% or more, “about 10% heating energy savings”, best on side tracks; closed draperies cut it by up to 10% (DOE, Energy Efficient Window Coverings). Film kits work the same way and also reduce condensation on cold windows too.

How do you seal a drafty double-hung or old sash window?
Lock it, V-strip the channels, tape the rails, then caulk the trim. DOE’s do-it-yourself project for double-hung windows rates the job at about 1 hour, $5 to $10 in materials and 5 to 10% energy savings (DOE DIY project).
- Clean and dry the jambs and sash edges; DOE says weatherstrip goes on above 20°F.
- Raise the lower sash, press V-strip into both side channels, tack it with finish nails and check the sash does not catch.
- Lower the upper sash and do its channels and its top edge.
- Strip the bottom of the lower sash with the V opening upward so it compresses on closing.
- Lock it. A lock that no longer pulls the meeting rails together is your meeting rail draft.
On old houses the bigger leak is often hidden. DOE notes a gap of about 1/4 to 1/2 inch on all four sides between the window and the framed opening, behind the trim, to be filled with non-expanding foam because expanding foam can bind the window. That is an owner job. Outside caulking wants old caulk scraped out and a dry day above 45°F.
What stops drafts from sliding windows, casements and sliding glass doors?
Sliders need a seal that tolerates sliding, so DOE lists fin seal, a pile weatherstrip with a Mylar fin in the middle, specifically for aluminum sliding windows and sliding glass doors, and magnetic strips for double-hung and sliding channels (DOE, Weatherstripping).
Casement and awning windows seal by compression against a gasket on the stop; DOE points to tubular vinyl or reinforced silicone there. Check the latch first. For doors, DOE’s table lists a sweep or door shoe, a bulb threshold, and one continuous strip along each side of the jamb. A garage door is a different problem with its own heat loss math, covered in our garage door insulation guide.

What can a renter do without damaging the window?
Use things that peel off: rope caulk, self-stick foam tape, a shrink film kit and a tight shade or interior panel. DOE suggests “low-cost plastic sheets over the windows” when replacement is out of reach, and curtains hung close to the glass with sides sealed by Velcro or magnetic tape.
Interior storm inserts are the renter version of a storm window. In a turn of the century Seattle house, PNNL measured a 21.1% drop in HVAC energy use after acrylic inserts went in, and a blower door test fell from 2,450 to 2,240 CFM50, an 8.6% cut in whole-house leakage (PNNL-22855). It is one house that was already air sealed. Do not seal shut a bedroom window that is someone’s way out in a fire; use a removable layer there. Income-eligible renters can also apply to the Weatherization Assistance Program; for a rental unit the local agency needs “the written permission of the owner or his agent” under 10 CFR 440.22.
Are storm windows worth it, or should drafty windows be replaced?
For leaky old windows in good repair, low-e storm windows usually come first. DOE says they deliver energy savings similar to replacement “at about 1/3 of the cost”, can cut overall home air leakage by 10% or more, and save 10% to 30% on heating and cooling depending on the window already there (DOE, Storm Windows).
PNNL’s summary of field studies lists a 21% heating load cut and 7% leakage cut in six Chicago homes with single-pane wood windows, and about 15% heating savings with 17% less infiltration across 10 Atlanta homes (PNNL-24827). In PNNL’s own matched Lab Homes, interior low-e storms saved 8.1% in the heating season but did not significantly reduce air leakage, because the double-pane primary windows “were already well-sealed”. A storm panel stops drafts only where the window behind it leaks.
The windows are sealed but the room is still cold: what next?
Check the rest of the wall, then the heat. DOE’s indoor leak list includes baseboards (British “skirting boards”), outlets and switch plates, and its air sealing page calls for caulk at wall to floor joints and foam gaskets behind outlet covers (DOE, Air Sealing Your Home). Outlets have their own fixes in our guide to cold air coming from electrical outlets.
A blower door test during a home energy audit shows every path at once. If the room stays cold with the air still, measure the supply air; our page on a furnace running but the house not warming up walks through the temperature rise check.
Frequently asked questions
What is the best window draft stopper?
It depends on where the air enters. For double-hung side channels, DOE rates a tension seal (V-strip) as durable, invisible and very effective; for aluminum sliders and sliding glass doors it lists fin seal pile. A fabric snake on the sill blocks only the bottom rail, not the meeting rail, the side channels or cold glass.
Can drafty windows be fixed without replacing them?
Usually, yes. DOE rates weatherstripping a double-hung window as a 1 hour job costing $5 to $10 in materials, and says low-e storm windows save about as much as replacement at about one-third the cost. Replacement makes more sense when the sash is rotted or the frame is out of square, so seals cannot close.
How do you stop drafts under doors?
Fit a door sweep or door shoe to the bottom of the door and check the threshold. DOE’s weatherstripping table lists sweeps for the interior side of in-swinging doors, door shoes that shed rain outside, and bulb thresholds that combine a threshold and seal. Then weatherstrip the full jamb with one continuous strip per side, tight at the corners.
How do you stop drafts under skirting boards?
Skirting boards are baseboards in US terms, and the gap is usually where the wall meets the floor behind them. DOE’s air sealing guidance says to caulk interior wall to floor joints, and to look for dirty streaks on carpet along the wall, which mark where air is moving. Larger gaps take low-expansion foam before the board goes back on.
How we researched this
We read seven DOE Energy Saver pages (archived copies: the live energy.gov/energysaver URLs returned “page not found” on November 20, 2026), LBNL-44032 on window thermal comfort, PNNL-22855, PNNL-24827 and 10 CFR 440.22. The temperature table is our subtraction from LBNL Table 1. Contractor blogs and retailer pages were excluded as sources for any number, and product or installed prices were left out because no federal source publishes them. Research date: November 20, 2026.
Sources
- U.S. DOE Energy Saver. “Weatherstripping (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/weatherstripping. Accessed November 2026.
- U.S. DOE Energy Saver. “Caulking (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/caulking. Accessed November 2026.
- U.S. DOE Energy Saver. “Detecting Air Leaks (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/detecting-air-leaks. Accessed November 2026.
- U.S. DOE Energy Saver. “Air Sealing Your Home (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/air-sealing-your-home. Accessed November 2026.
- U.S. DOE Energy Saver. “Weatherstrip Double-Hung (or Sash) Windows (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/do-it-yourself-savings-project-weatherstrip-double-hung-or-sash-windows. Accessed November 2026.
- U.S. DOE Energy Saver. “Storm Windows (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/storm-windows. Accessed November 2026.
- U.S. DOE Energy Saver. “Energy Efficient Window Coverings (archived).” https://web.archive.org/web/2025id_/https://www.energy.gov/energysaver/energy-efficient-window-attachments. Accessed November 2026.
- LBNL. “Window Performance for Human Thermal Comfort (LBNL-44032).” https://windows.lbl.gov/sites/default/files/lbnl-44032.pdf. Accessed November 2026.
- PNNL. “Energy Savings and Thermal Comfort From Interior Storm Windows (PNNL-22855).” https://www.pnnl.gov/main/publications/external/technical_reports/PNNL-22855.pdf. Accessed November 2026.
- PNNL. “Evaluation of Interior Low-E Storm Windows in the PNNL Lab Homes (PNNL-24827).” https://www.pnnl.gov/main/publications/external/technical_reports/PNNL-24827.pdf. Accessed November 2026.
- eCFR. “10 CFR 440.22.” https://www.ecfr.gov/current/title-10/section-440.22. Accessed November 2026.

Leave a Reply