Last reviewed: November 2026 · By the HVAC Brief Editorial Team · Our sourcing and editorial standards
Of the 284,747 heat pump systems on the ENERGY STAR certified list in November 2026, 148,258 (52.1%) carry the cold climate designation, meaning they keep at least 70 percent of their heating capacity at 5°F with a coefficient of performance of at least 1.75. Counted by outdoor unit, 9,525 of 12,688 models (75.1%) have at least one cold-climate configuration. The designation tracks the compressor almost perfectly: 86.2% of variable-speed systems qualify, against one single-stage system out of 50,461.
This report counts every certified system and outdoor model on the full ENERGY STAR list (updated November 12, 2026) by type, brand, manufacturer, refrigerant and launch year, and explains what the 5°F rating means on a cold night in Minneapolis.
Executive summary
ENERGY STAR lists 284,747 certified air-source heat pump systems, each a specific outdoor unit matched with an indoor coil or air handler, built around 12,688 outdoor-unit models sold under 269 brand names by 150 ENERGY STAR partners.
Ductless equipment leads. 85.1% of mini and multi split systems qualify and their median system keeps 84% of its 47°F capacity at 5°F; for ducted split systems the figures are 49.8% and 70%. 43.8% of ducted systems keep less than 60 percent and need backup heat in a northern winter.
The market is moving toward cold-climate equipment: 63.2% of listed outdoor models first sold in 2023 are cold-climate rated, rising to 87.9% for 2026 launches. The R-410A share of new outdoor models fell from 91.2% to 6.2%.
Key findings
- 148,258 of 284,747 ENERGY STAR certified heat pump systems (52.1%) are designated cold climate; 9,525 of 12,688 outdoor models (75.1%) have at least one cold-climate configuration.
- The median certified system keeps 70.8% of its 47°F heating capacity at 5°F: 84% for mini and multi splits, 70% for ducted splits and 64% for single-package units. Counted once per outdoor model instead of once per indoor and outdoor pairing, the median is 76% across 12,688 outdoor models, because large ducted product lines are certified in dozens of pairings each.
- Compressor type decides it: 86.2% of variable-speed systems are cold-climate rated, 12.7% of two-stage systems and 1 of 50,461 single-stage systems.
- 99.4% of systems meet the 1.75 COP minimum at 5°F; capacity, not efficiency, is the binding test.
- A median 3-ton cold-climate system delivers 28,200 Btu/h at 5°F; a median 3-ton system without the designation delivers 18,400 Btu/h, 34.8% less.
- Among 37 brands with 100+ outdoor models, cold-climate shares run from 94.2% (TCL, excluding two through-the-wall makers at 100%) to 43.3% (Trane).
cold-climate-heat-pump-statistics-data.csv: 737 rows, one per outdoor-unit brand, product type and cold-climate designation, covering all 284,740 certified systems with a designation. Columns: brand, energy_star_partner, product_type, cold_climate_designation, certified_system_combinations, outdoor_unit_models, median_capacity_5F_pct_of_47F, median_cop_at_5F, median_hspf2_btu_per_wh, median_seer2_btu_per_wh, median_heating_capacity_47F_btu_h, median_heating_capacity_5F_btu_h, variable_speed_pct, r410a_pct, r454b_pct, r32_pct, source. Free to reuse with credit to The HVAC Brief and a link to this page.
What a cold climate heat pump is, in numbers
ENERGY STAR’s Version 6.1 specification, in effect since January 1, 2023, lets a heat pump carry the cold climate designation if it meets four tests: SEER2 of at least 15.2 and HSPF2 of 8.1 (8.5 for ductless); a coefficient of performance (COP) at 5°F of at least 1.75, meaning 1.75 units of heat per unit of electricity; heating capacity at 5°F of at least 70 percent of capacity at 47°F; and a controls verification test showing the unit’s own controls reach those numbers.
The list holds 284,747 certified systems. A ducted outdoor unit is certified with many indoor coils and furnaces, so the 4,365 ducted outdoor models produce 265,853 systems, about 61 each, while the 7,498 ductless outdoor models produce 18,049. Systems show what a buyer can install; outdoor models show what manufacturers build.
| Type | Certified systems | Outdoor models | Cold climate (systems) | Cold climate (outdoor models) | Median 5°F/47°F capacity | Keep 70%+ at 5°F | Median COP at 5°F | Variable speed |
|---|---|---|---|---|---|---|---|---|
| Ducted split | 265,853 | 4,365 | 49.8% | 62.8% | 70% | 52.1% | 2.04 | 54% |
| Mini or multi split | 18,049 | 7,498 | 85.1% | 84.0% | 84% | 88.0% | 2.00 | 100% |
| Single package | 845 | 825 | 59.4% | 58.4% | 64% | 39.4% | 1.77 | 60% |
| All | 284,747 | 12,688 | 52.1% | 75.1% | 71% | 54.3% | 2.02 | 57% |
Single-package units, with the whole heat pump in one cabinet, are weakest at 5°F, with a median of 64%.
Source: ENERGY STAR Certified Air-Source Heat Pumps, data.energystar.gov (list updated November 12, 2026). HVAC Brief analysis. Unit: certified system combinations with valid 5°F and 47°F capacity.
How much heat survives at 5°F
Capacity at 5°F divided by capacity at 47°F is the single most useful number on a heat pump spec sheet for a cold-climate buyer. Across the 12,688 outdoor models, 74.3% reach at least 70 percent and 11.9% reach 100 percent or more. Systems split into two clusters: conventional units at 50 to 59 percent and variable-speed units at 70 to 89 percent.
Source: ENERGY STAR Certified Air-Source Heat Pumps, data.energystar.gov (list updated November 12, 2026). HVAC Brief analysis. Median across each outdoor model’s certified combinations. The ENERGY STAR cold-climate line is 70%.
Ductless systems hold the top of the range. 19.8% of mini and multi split systems are rated to deliver at least as much heat at 5°F as at 47°F. For ducted systems that figure is 0.7%.
What 5°F capacity means for a home in Minneapolis
Minneapolis-St. Paul International Airport recorded an average of 32.6 nights a winter at or below 5°F over the winters ending 1991 to 2020, and 13.1 nights at or below minus 5°F. Last winter (July 2025 to June 2026) it had 29 such nights and a low of -21°F. Chicago averaged 12.4 nights and Boston 2.8.
Source: NOAA NCEI, GHCN-Daily station records (daily minimum temperature). HVAC Brief count, winters ending 1991 to 2020; Denver has 23 complete winters.
The table converts the ratings into output. A median 3-ton (36,000 Btu/h cooling) cold-climate system is rated at 36,200 Btu/h at 47°F and 28,200 Btu/h at 5°F. A median 3-ton system without the designation starts at 34,800 and falls to 18,400. For a Minneapolis house that needs 30,000 Btu/h on a 5°F night, the first covers almost all of it and the second about 60 percent, with resistance strips or a furnace doing the rest. Your design load comes from a Manual J calculation, not these medians.
| Nominal size | Designation | Systems | Output at 47°F | Output at 5°F | Median 5°F/47°F |
|---|---|---|---|---|---|
| 2 ton | Cold climate | 40,623 | 24,600 | 21,200 | 86% |
| 2 ton | Not cold climate | 32,695 | 23,200 | 11,200 | 49% |
| 3 ton | Cold climate | 26,248 | 36,200 | 28,200 | 75% |
| 3 ton | Not cold climate | 23,462 | 34,800 | 18,400 | 52% |
Our heating degree days by city report shows how much heating each metro needs over a season, and our cost to run a heat pump analysis turns that into a bill. Below 5°F, where certified data stops, see our report on whether heat pumps work in cold weather.
Our heat pumps in new homes report tracks adoption by region, and our heat pump versus gas furnace comparison prices backup heat.
Cold climate heat pumps by brand
Many brands share factories. Heil, Tempstar, Comfortmaker, Arcoaire, KeepRite, AirQuest and Day & Night are all listed by Carrier Corporation with nearly identical model sets, so they post the same results. Of the 269 brand names, 144 have at least 20 outdoor models and 37 have at least 100. The table ranks all 37 by cold-climate share of outdoor models.
| Rank | Brand | Outdoor models | Cold climate share | Median 5°F/47°F |
|---|---|---|---|---|
| 1 | Ephoca | 190 | 100% | 67% |
| 2 | Innova | 187 | 100% | 72% |
| 3 | TCL | 137 | 94% | 77% |
| 4 | Innovair | 121 | 93% | 83% |
| 5 | Gree | 257 | 91% | 81% |
| 6 | Mainline | 100 | 89% | 78% |
| 7 | Tosot | 294 | 89% | 79% |
| 8 | AUX | 101 | 87% | 81% |
| 9 | MDV | 294 | 86% | 80% |
| 10 | 1HVAC | 105 | 86% | 84% |
| 11 | Hisense | 201 | 82% | 77% |
| 12 | Midea | 362 | 80% | 74% |
| 13 | Blueridge | 202 | 80% | 78% |
| 14 | Payne | 120 | 78% | 80% |
| 15 | LG | 125 | 76% | 77% |
| 16 | Fujitsu | 130 | 75% | 88% |
| 17 | ACIQ | 134 | 74% | 76% |
| 18 | Smart Comfort | 122 | 70% | 77% |
| 19 | MRCOOL | 110 | 70% | 75% |
| 20 | Weathermaker | 131 | 67% | 76% |
| 21 | Mitsubishi Electric | 272 | 67% | 74% |
| 22 | AC Pro | 118 | 64% | 73% |
| 23 | Comfortmaker | 187 | 62% | 72% |
| 24 | AirQuest | 189 | 61% | 72% |
| 25 | Arcoaire | 189 | 61% | 72% |
| 26 | KeepRite | 189 | 61% | 72% |
| 27 | Tempstar | 189 | 61% | 72% |
| 28 | Carrier | 201 | 61% | 72% |
| 29 | Heil | 190 | 61% | 72% |
| 30 | Day & Night | 191 | 61% | 72% |
| 31 | Friedrich | 117 | 61% | 70% |
| 32 | York | 106 | 58% | 74% |
| 33 | Trane / Mitsubishi Electric | 144 | 58% | 79% |
| 34 | Bryant | 219 | 56% | 71% |
| 35 | Kenmore | 161 | 55% | 70% |
| 36 | Lennox | 158 | 53% | 72% |
| 37 | Trane | 104 | 43% | 64% |
Source: ENERGY STAR Certified Air-Source Heat Pumps, data.energystar.gov (list updated November 12, 2026). HVAC Brief analysis. Partners ranked by certified systems; highlighted: the four largest, which hold 83.6% of systems.
Ductless-focused brands listed by Gree, GD Midea, TCL and Hisense rank high, at 82 to 94 percent. Among the best-known residential names, Mitsubishi Electric has 66.9% of 272 outdoor models designated, Fujitsu 75.4% with the highest median capacity ratio in the table (88%), Carrier 61.2%, Lennox 53.2%, Rheem 63.7% and Trane 43.3%. Trane’s median outdoor model keeps 64% at 5°F and Rheem’s 59%, reflecting large single- and two-stage ranges. Ephoca and Innova, through-the-wall packaged units, score 100 percent on the designation despite median listed ratios near 70 percent.
By manufacturer, Carrier Corporation lists 2,820 outdoor models across 24 brands, and 51.6% of all certified systems (22.2% of outdoor models). With Johnson Controls, Lennox and Trane, the top four hold 83.6% of systems. Lennox has the lowest cold-climate share of the four (30.7% of outdoor models).
The trend: new models, new refrigerants
The list holds only models still certified, and every certification dates from 2023 or later, so we track the year each model was first on the market instead of certification year. Among outdoor models still listed, launches peaked at 3,838 in 2024 during the refrigerant changeover, then fell to 2,753 in 2025 and 1,491 so far in 2026.
Source: ENERGY STAR Certified Air-Source Heat Pumps, data.energystar.gov (list updated November 12, 2026). HVAC Brief analysis. Currently listed models only; 2026 through November 9. Ducted line starts in 2021, the first year with 50 or more ducted models.
| Year on market | Outdoor models | Cold climate | Ducted models | Ducted cold climate | R-410A | Variable speed | Median 5°F/47°F |
|---|---|---|---|---|---|---|---|
| 2018 | 1,146 | 86.7% | 239 | 82.0% | 29.5% | 99.9% | 83% |
| 2019 | 194 | 67.0% | 15 | n<50 | 94.3% | 100.0% | 79% |
| 2020 | 192 | 79.2% | 21 | n<50 | 83.8% | 100.0% | 85% |
| 2021 | 123 | 60.2% | 54 | 53.7% | 100.0% | 91.1% | 74% |
| 2022 | 1,475 | 62.9% | 502 | 55.4% | 94.6% | 86.2% | 75% |
| 2023 | 1,323 | 63.2% | 605 | 61.2% | 91.2% | 71.1% | 71% |
| 2024 | 3,838 | 71.9% | 1,618 | 52.4% | 16.7% | 78.2% | 77% |
| 2025 | 2,753 | 80.2% | 889 | 74.1% | 6.0% | 88.0% | 74% |
| 2026 | 1,491 | 87.9% | 420 | 79.0% | 6.2% | 95.6% | 78% |
EPA’s Technology Transitions rule set a global warming potential (GWP) limit of 700 for new residential split systems installed from January 1, 2026 (EPA revised parts of the rule in May 2026). R-410A’s GWP is 2,088, R-454B’s 470. Across the whole list, 80.5% of systems use R-454B, 17.5% R-410A and 2.0% R-32. R-410A systems that remain listed are less often cold-climate rated (26.4%) than R-454B systems (56.6%) or R-32 systems (91.4%). Our A2L refrigerant tracker follows the switch.
Efficiency ratings: SEER2 and HSPF2
The median certified ducted split is rated SEER2 16.2 and HSPF2 8.5; the median mini or multi split SEER2 21.0 and HSPF2 10.0. 20.5% of ductless systems reach HSPF2 11 or higher; no ducted split system does. HSPF2 is a reasonable first filter for cold performance: across all systems its correlation with the 5°F capacity ratio is 0.69, and only 10.4% of the 87,424 systems rated HSPF2 9.0 or better lack the cold-climate designation.
Original synthesis (HVAC Brief calculations)
1. Capacity, not efficiency, is what fails in the cold
Nearly every certified heat pump clears the efficiency half of the cold-climate test at 5°F: 99.4% report a COP of 1.75 or more. What separates designated units is how much heat they still produce. At the system level, capacity ratio and COP at 5°F are negatively correlated (r = -0.44). Single-stage systems have the highest median COP at 5°F (2.10) and the lowest capacity ratio (50%): a fixed-speed compressor runs efficiently but cannot move enough heat. Variable-speed systems give up a little efficiency (1.98) and keep 76%. Compare capacity ratio first.
2. The US-only list is the warm-climate list
Each listing names its markets. Of the 25,432 systems listed for the United States only, 17.2% are cold-climate rated, with a median capacity ratio of 52%. Of the 1,639 systems listed for Canada only, 77.7% are, with a median of 75%.
3. The label and the numbers do not always agree
8,628 systems without the designation report SEER2, HSPF2, COP and capacity values that meet every numeric threshold; most of them have the controls verification test on file. Conversely, 2,770 designated systems list a 5°F capacity under 70 percent of the 47°F figure shown, because the specification measures 47°F at a nominal speed. Check the capacity figures for the exact pairing you are quoted.
Charts worth building from this data
- Scatter of 5°F capacity ratio against COP at 5°F for all outdoor models, by compressor type.
- Refrigerant share by certification quarter, 2024 to 2026.
- Capacity ratio distribution for each of the 20 largest brands.
Most quotable statistics
- Only 52.1% of the 284,747 ENERGY STAR certified heat pump systems listed in November 2026 carry the cold climate designation (HVAC Brief analysis of ENERGY STAR data, 2026).
- The median ENERGY STAR certified heat pump keeps 71% of its heating capacity at 5°F, compared with 84% for ductless mini-splits (HVAC Brief analysis of ENERGY STAR data, 2026).
- 86.2% of variable-speed heat pumps on the ENERGY STAR list are cold-climate rated, against 1 of 50,461 single-stage systems (HVAC Brief, ENERGY STAR data, 2026).
- 87.9% of heat pump outdoor models launched in 2026 are rated for cold climates, up from 63.2% of 2023 launches (HVAC Brief analysis of ENERGY STAR data, 2026).
- A median 3-ton cold-climate heat pump delivers 28,200 Btu/h at 5°F, 53.3% more than a median 3-ton model without the designation (HVAC Brief analysis of ENERGY STAR ratings, 2026).
- Minneapolis averages 33 nights a winter at or below 5°F, the temperature at which ENERGY STAR tests cold-climate heat pumps (HVAC Brief analysis of NOAA data, 1991-2020).
Data limitations
- Only ENERGY STAR certified products are counted. Many basic single-stage heat pumps are not certified, so the cold-climate share of all heat pumps sold is lower.
- Counts are of certified configurations and models, not units sold; ENERGY STAR publishes no shipments by model.
- Only currently certified models are listed, so launch-year counts are survivors, not historical growth.
- Low-temperature figures are as reported. 2,739 systems with a missing or implausible capacity ratio (below 20 or above 150 percent) and 831 with a COP at 5°F outside 1.0 to 5.0 are excluded from those statistics only. Seven systems have no designation entered.
- Defrost, installation, duct losses and temperatures below 5°F change real output.
- Brands share manufacturers and model families, so brand rankings are not independent.
Downloadable dataset: recommended fields
| Field | Description |
|---|---|
| brand | Outdoor-unit brand name, standardized spelling |
| energy_star_partner | Main listing partner |
| product_type | Ducted split, Mini or multi split, Single package |
| cold_climate_designation | Yes or No, as listed |
| certified_system_combinations | Certified outdoor/indoor pairings |
| outdoor_unit_models | Distinct outdoor models |
| median_capacity_5F_pct_of_47F | Median heating capacity at 5°F as a percent of 47°F |
| median_cop_at_5F | Median coefficient of performance at 5°F |
| median_hspf2_btu_per_wh, median_seer2_btu_per_wh | Median efficiency ratings |
| median_heating_capacity_47F_btu_h, _5F_btu_h | Median rated heating output |
| variable_speed_pct | Share with a continuously variable compressor |
| r410a_pct, r454b_pct, r32_pct | Refrigerant shares |
| source | Dataset and list date |
| Download | cold-climate-heat-pump-statistics-data.csv (CC BY 4.0), 737 rows by 17 columns |
Press summary
Only 52.1% of the 284,747 heat pump systems on the ENERGY STAR certified list are rated for cold climates, according to an HVAC Brief analysis of the November 2026 list. Ductless mini-splits qualify far more often (85.1%) than ducted systems (49.8%), and 86.2% of variable-speed systems qualify against almost no single-stage units. The share is rising fast: 87.9% of outdoor models launched in 2026 carry the designation.
Suggested headlines
- Only half of certified heat pumps are rated for cold climates
- Nearly 9 in 10 new heat pump models now built for the cold
- Ductless heat pumps beat ducted systems in the cold, federal data show
Source quality ranking
| Source | Tier | Why |
|---|---|---|
| ENERGY STAR Certified Air-Source Heat Pumps (data.energystar.gov) | Tier 1 | Federal certification list; every certified system, manufacturer-reported and third-party certified ratings |
| ENERGY STAR Central AC and Heat Pump Specification Version 6.1 | Tier 1 | Defines the cold climate criteria used here |
| EPA Technology Transitions HFC rule fact sheet | Tier 1 | Refrigerant GWP limits and compliance dates |
| NOAA NCEI GHCN-Daily | Tier 1 | Quality-controlled daily station temperatures |
Methodology
- Downloaded the full ENERGY STAR Certified Air-Source Heat Pumps dataset (w7cv-9xjt, 284,747 rows, updated November 12, 2026) on November 16, 2026; the ducted (266,698) and mini-split (18,049) subsets reconcile to it.
- Capacity ratio = Heating Capacity at 5°F divided by Heating Capacity at 47°F for each listed system. Outdoor-model figures use the median across that model’s certified combinations; a model counts as cold climate if any combination is designated.
- Brand spellings were standardized. Launch year is each outdoor model’s earliest Date Available on Market. Size classes use cooling capacity within 5 percent of 24,000 and 36,000 Btu/h.
- Nights at or below 5°F count GHCN-Daily minimum temperatures, excluding flagged values, for July-to-June winters with at least 90 percent of days reported.
- Verification: ENERGY STAR’s own API counts match ours exactly for cold-climate systems (148,258), compressor staging (161,115 variable-speed), refrigerant (229,217 R-454B) and ductless cold-climate systems (15,354).
- The brand-level CSV is published with this report (link above) under CC BY 4.0.
Frequently asked questions
What is a cold climate heat pump?
Under ENERGY STAR Version 6.1, one that keeps at least 70 percent of its 47°F heating capacity at 5°F, has a COP of at least 1.75 at 5°F, meets SEER2 15.2 and HSPF2 8.1 (8.5 ductless) and passes a controls test.
How many heat pumps are cold-climate rated?
148,258 of 284,747 ENERGY STAR certified systems (52.1%) as of November 2026, built on 9,525 of 12,688 outdoor models.
Do heat pumps work at 5°F?
Yes. The median certified system keeps 71% of its 47°F capacity at a COP of 2.02, twice the heat per kWh of electric resistance.
Are ductless mini-splits better in the cold than ducted heat pumps?
On certified ratings, yes. 85.1% of mini and multi split systems are cold-climate rated against 49.8% of ducted splits, and their median capacity ratio is 84% against 70%.
Can a single-stage heat pump be cold climate?
Practically no. One of 50,461 certified single-stage systems carries the designation; their median system keeps 50% of capacity at 5°F.
Which brands have the most cold climate heat pumps?
By count, Midea (289 cold-climate outdoor models), then Tosot and MDV.
How much heat does a 3-ton heat pump give at 5°F?
The median 3-ton cold-climate system is rated at 28,200 Btu/h at 5°F; the median 3-ton system without the designation at 18,400 Btu/h.
Do I need a cold climate heat pump in Minneapolis?
If you want the heat pump to carry most of the load, yes. Minneapolis averages 32.6 nights a winter at or below 5°F and 13.1 at or below minus 5°F. Check heat pump rebates before you buy.
Do cold climate heat pumps use R-454B?
Most do: 80.5% of listed systems use R-454B, and 56.6% of those are cold-climate rated.
Are geothermal heat pumps included?
No. This report covers air-source heat pumps. Ground-source units do not lose capacity with air temperature; see our geothermal heat pump statistics.
Cite this report
Sources
- US EPA, ENERGY STAR Certified Air-Source Heat Pumps, dataset w7cv-9xjt, updated November 12, 2026.
- ENERGY STAR Certified Ducted Heat Pumps, dataset 3m3x-a2hy and Certified Mini-Split Heat Pumps, dataset akti-mt5s.
- ENERGY STAR Program Requirements, Central Air Conditioner and Heat Pump Equipment, Version 6.1.
- US EPA, Technology Transitions HFC restrictions by sector, and October 2023 final rule fact sheet.
- NOAA National Centers for Environmental Information, Global Historical Climatology Network Daily.
The HVAC Brief is an independent trade publication. We do not sell equipment, take manufacturer advertising, or accept payment for placement in our research. Corrections welcome.

Leave a Reply