Does the outside AC unit run when the heat is on? Only if it is a heat pump. With a gas or oil furnace and central AC, the outdoor unit should stay silent in heat mode. A heat pump’s outdoor unit is the heater and runs all winter; a dual fuel system switches it off below a set outdoor temperature.
| Your system | Outdoor unit in HEAT | Normal sights and sounds | Red flag |
|---|---|---|---|
| Gas or oil furnace + central AC | Off: heat runs R to W; the outdoor unit starts only on R to Y | Silence outside; burners and blower at the furnace | Outdoor fan or compressor running while the furnace heats |
| Heat pump with air handler | On: it is the heat source | Long cycles; frost; fan stops and steam rises in defrost | Ice that survives defrost; no warm air after 5 minutes |
| Heat pump on EM HEAT | Off: Rheem says it is locked off | Silence outside; electric strips heat | Days on EM HEAT: a high bill |
| Dual fuel (heat pump + furnace) | On above the switchover temperature, off below it | Outdoor unit stops as the furnace lights | Both running on a standard furnace-coil setup |
| Ductless mini split heat pump | On, with stops of 7 to 15 minutes for defrost (Fujitsu) | Steam from the outdoor unit, sizzling, flashing OPERATION lamp | Blinks that repeat after defrost ends |
Gas furnace with central AC: why should the outside unit sit still when the heat is on?
Because the heat call never reaches it. In Goodman’s gas furnace service instructions, a call for heat begins when the “R and W thermostat contacts close”, while the outdoor fan and compressor are energized only when R and Y close for a cooling call (Goodman furnace sequence of operation, page 71).
W runs to the furnace board and Y to the outdoor contactor coil, as our thermostat wiring color guide shows. In HEAT the thermostat closes R to W, not R to Y, so the 24 V contactor coil gets nothing and the 208/230 V side stays open. Under 10 CFR 430.2, a central air conditioner “is a heat pump or a cooling unit only”, and a cooling-only unit has no job in January.
Carrier’s 25HNB6 diagram says its crankcase heater “is energized during off cycle below 65ºF”, so a warm compressor shell with the fan still can be normal; Rheem asks installers to allow 24 hours of power for such a heater before checkout. A louder buzz is covered under outside AC unit humming.
Heat pump: why does the outside unit run for hours on a 25°F night?
Because the outdoor unit is the heater. Rheem’s heat pump manual describes the outdoor coil extracting heat from winter air “as refrigerant evaporates” and the compressor carrying it to the indoor coil (Rheem 708163b, pages 2 and 3).
Colder air holds less heat, so cycles stretch out. When the compressor falls behind, the thermostat adds electric strips through AUX or W2; Rheem’s optional outdoor thermostat keeps them off above a set point adjustable from 45°F to 0°F. The outdoor unit should stop only on EM HT: Rheem says “the outdoor unit will be locked off” and resistance heat takes over, which our auxiliary heat vs emergency heat page prices out.
If the outdoor unit runs in HEAT but the vents blow cool, the Resideo RTH6360 guide points to setup option 200 or 218. Option 200 tells the thermostat it controls a heat pump; option 218 sets whether the O/B terminal energizes the reversing valve in cool (O) or in heat (B).

Fan stopped, steam rising, a whoosh: is the heat pump defrosting or failing?
Almost always defrosting. Rheem calls frost on the outdoor coil in cold weather “normal”: during defrost the outdoor fan stops, the compressor keeps running to heat the coil, and afterwards “some steam may rise from the outdoor unit” (Rheem 708163b, page 3). Rheem’s board even offers a 30 second compressor delay to soften the whoosh going into and out of defrost.
The Carrier 25HNB6 diagram and other manuals give the exact windows:
| Document | What stops | Stated timing |
|---|---|---|
| Carrier 25HNB6 heat pump wiring diagram | Outdoor fan during defrost; defrost only below 50°F outdoors with the coil under 32°F | Every 90 minutes from the factory (30, 60 or 120 selectable); ends at a 65°F coil; fan restarts 20 seconds later |
| Rheem 708163b outdoor heat pump | Outdoor fan during defrost; compressor keeps running | 30, 60 or 90 minute interval; defrost ends after 10 minutes if the sensor has not opened at 68°F |
| Fujitsu Halcyon mini split FAQ | Whole unit during automatic defrosting | Between 7 and 15 minutes |
| Rheem, Carrier, Resideo | Outdoor unit after a mode change or power cut | About 5 minutes of compressor protection |
Ice that thickens over several cycles, or a fan stopped far longer than 10 minutes, is a failed defrost; see ice on outside AC unit and the heat pump defrost cycle explainer.
Dual fuel: at what outdoor temperature does the outside unit stop and the furnace take over?
At the switchover temperature your installer sets; there is no factory number. NEEA’s 2026 dual fuel analysis defines switchover as the temperature at which the system moves from heat pump to gas, and it modeled switchovers of 30°F, 35°F and 40°F for one Portland house (NEEA dual fuel control analysis).
Below it the outdoor unit should be still. Goodman’s AFE18-60A kit, for a coil above the furnace, “will turn the heat pump unit off when the furnace is turned on” and adds a 3 minute off delay (Goodman accessories list, page 12). NEEA’s “supplemental” design, with a hot water coil after the heat pump coil, is the exception that runs both. Switchover cost math is on our dual fuel heat pump page.
Ductless mini split: why does the outdoor unit stop for 7 to 15 minutes in heat mode?
It is defrosting. Fujitsu’s owner FAQ says that during heating “the outdoor unit’s fan may stop, and steam may be seen rising from the unit”, that the unit “will temporarily stop operating (between 7 and 15 minutes)” for automatic defrosting, and that the OPERATION lamp flashes meanwhile (Fujitsu troubleshooting FAQ).
Two more stops are normal: past the setpoint the outdoor unit stops and the indoor fan runs at very low speed, and after a stop or power cut the compressor waits about 3 minutes. A blink that repeats once heating resumes is a fault code; see our Fujitsu mini split error codes page.
How do you tell a heat pump from a cooling-only AC in five minutes?
Read the labels, then run the maker’s test. The outdoor data label names the product, such as Carrier’s 25HNB6 “2-Stage Heat Pump”. On a Resideo RTH6360 thermostat, setup option 200 reads 1 for conventional forced air, 2 for heat pump and 5 for cool only, and Em Heat appears only “for heat pumps with auxiliary heat” (Resideo RTH6360 guide, pages 9 and 10). So is a wire on O/B.
The test is Rheem’s startup checkout (Rheem 708163b, page 10). Set the system to HEAT with the setpoint at its lowest, wait at least 5 minutes for the protective timer, then raise the setpoint to the top. A heat pump starts its outdoor unit; a furnace system lights its burners and leaves it still.

Outside AC running while the furnace heats: stuck contactor, AUTO mode or a shorted wire?
On a furnace with a cooling-only AC, an outdoor unit running in HEAT is a fault. Trane’s troubleshooting guide says that if the compressor contactor “becomes welded closed, the AC unit will continue running with constant power” (Trane). Carrier’s 25HNB6 board even flashes code 73, “Contactor Shorted”, for it; our HVAC contactor page shows how it fails.
Rule out AUTO first: in that mode the RTH6360 “selects heating or cooling as needed”, so a sunny winter afternoon can start cooling. Then set the thermostat to OFF. If the outdoor unit keeps running, open its disconnect; the order of checks is on our AC won’t turn off page.
Stop there: the contactor switches 208/230 V line power. The technician measures the contactor coil with the thermostat at OFF. Zero volts across the coil with the contacts still closed means welded contacts; 24 V present means a shorted Y wire or a thermostat fault upstream.
Frequently asked questions
Why is my AC unit leaking water outside in winter?
On a heat pump it is usually defrost meltwater. Goodman’s GSZ16 manual says heat pump bases have cutouts under the outdoor coil to drain frost, and suggests raising the unit 2 1/2″ where the design temperature is +15°F or above and 8″ from -5°F to +14°F.
Why is my AC unit not running outside when the heat is on?
With a gas furnace and central AC that is correct. On a heat pump, check that the thermostat is not on Em Heat, which per Resideo does not use the compressor, that Heat On is not flashing through its 5 minute protection, and that a dual fuel control has not handed heating to the furnace.
Why does my AC unit turn on outside but not inside?
In heat mode a short gap is often by design. Fujitsu says its mini splits run the indoor fan at very low speed when heating starts so internal parts can warm up, and Goodman’s two-stage gas furnaces start the blower only after a fixed 30 second delay once the burners light.
Can an outside AC unit catch fire, or is that steam?
Steam during winter heating is normal on a heat pump: Rheem writes that after defrost some steam may rise as the warm coil evaporates meltwater, and Carrier’s 25HNB6 restarts its fan 20 seconds after defrost ends. Steam fades once the coil dries; smoke with a burning smell does not. For smoke, open the outdoor disconnect and call for service.
How we researched this
Researched 7 and 8 November 2026 from the nine documents listed below: maker manuals from Goodman, Rheem, Carrier, Resideo, Fujitsu and Trane, NEEA’s March 2026 dual fuel analysis and 10 CFR 430.2. Timings apply to the named models. Ranking blog posts were excluded as sources because none cites a document. The DOE Energy Saver heat pump page returned not found and was not used.
Sources
- Goodman Manufacturing. “Service Instructions: 80%, 90%, 95% Gas Furnaces & Accessories.” https://s3.amazonaws.com/s3.supplyhouse.com/product_files/Goodman-GMS951155DXA-Install-Instructions.pdf. Accessed November 2026.
- Rheem Manufacturing. “Outdoor Heat Pump User’s Information/Installation Instructions, 13 SEER (708163b).” https://files.rheem.com/LiteratureArchive/708163b.pdf. Accessed November 2026.
- Carrier Corporation. “25HNB6 Infinity 16 2-Stage Heat Pump Wiring Diagram (25HNB6-1W).” https://www.partstown.com/modelManual/CRR-25HNB6-English_wd.pdf. Accessed November 2026.
- Goodman Manufacturing. “Condensing Unit / Heat Pump Installation and Service Reference (IOG-4002A).” https://cdn.shopify.com/s/files/1/0253/0852/8730/files/Goodman_GSZ16_Installation_Manual__1.pdf. Accessed November 2026.
- Resideo. “RTH6360 Series Programmable Thermostat Quick Installation Guide (33-00201EF).” https://digitalassets.resideo.com/damroot/Original/10015/33-00201EF.pdf. Accessed November 2026.
- Northwest Energy Efficiency Alliance (NEEA). “Dual-Fuel Gas Furnace + Heat Pump System Control Analysis.” https://neea.org/wp-content/uploads/2026/03/Dual-Fuel-Gas-Furnace-and-Heat-Pump-System-Control.pdf. Accessed November 2026.
- Fujitsu General America. “Current Owners FAQs and Troubleshooting: Halcyon.” https://www.fujitsugeneral.com/us/support/faq/halcyon/troubleshooting.html. Accessed November 2026.
- Trane. “AC Won’t Turn Off.” https://www.trane.com/residential/en/resources/troubleshooting/air-conditioners/ac-wont-turn-off/. Accessed November 2026.
- eCFR. “10 CFR 430.2, Definitions.” https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-A/section-430.2. Accessed November 2026.