Furnace filter size by model number takes two steps: find the cabinet width code in the model number (a letter A to D on Goodman, Lennox, York and Trane; 14, 17, 21 or 24 on Carrier, Bryant and Heil), then read that width in the maker’s filter table. Most tables give a 16 x 25 side filter at every width.
Filterbuy’s Carrier page says the model number “won’t tell you your filter size.” It never prints one, but on all seven series decoded below it prints the cabinet width, and each maker’s installation manual keys its filter table to that width.
Which characters in the furnace model number give the cabinet width?
The width code sits in a fixed position for each series. On a Goodman GM9S80 it is character 11, a letter where A is 14″, B is 17½”, C is 21″ and D is 24½”. Carrier’s 59SC6A manual lists furnace sizes such as 060M17 and 080M21, where 17 and 21 are the casing width in inches, and Bryant’s 915SA product data puts the width in characters 12 and 13 (14 is 14.2″, 24 is 24.5″).
Lennox puts the letter last: the ML180UH instructions list ML180UH070P36A with a 14-1/2″ cabinet and ML180UH110P60C with a 21″ cabinet. York’s TM9E manual puts it right after the input (TM9E080C16MP11 is a C, 21″ cabinet), and Trane’s modulating *UHM furnaces put it fifth (TUHMB080CCV3VA is a B, 17-1/2″). The serial number on the same plate gives the build date, not the size.

Furnace filter size by model number: what does each maker’s table say?
Read across the row for your width code. Sizes are nominal; “side” means a return on the left or right panel of an upflow furnace, which 5 of these 6 makers size at 16 x 25.
| Series (document) | Width code = cabinet | Side return filter | Bottom return filter |
|---|---|---|---|
| Goodman GM9S80 upflow | A = 14″ | 1, 16 x 25 | 1, 14 x 24 |
| Goodman GM9S80 | B = 17½” | 1, 16 x 25 | 1, 16 x 25 |
| Goodman GM9S80 0804C, 0805C | C = 21″ | 1, 16 x 25 | 1, 16 x 25 |
| Goodman GM9S80 1005C | C = 21″ | 2, 16 x 25 | 1, 20 x 25 |
| Goodman GM9S80 1205D | D = 24½” | 2, 16 x 25 | 1, 24 x 24 |
| Carrier 59SC6A, Heil N96MSN (3/4″ deep); Lennox ML180UH (1″ deep) | 14 or A = 14-3/16″ to 14-1/2″ | 16 x 25 | 14 x 25 |
| Carrier, Heil, Lennox | 17 or B = 17-1/2″ | 1, 16 x 25 | 1, 16 x 25 |
| Carrier, Heil, Lennox | 21 or C = 21″ | 1, 16 x 25 | 1, 20 x 25 |
| Carrier 59SC6A, Heil N96MSN | 24 = 24-1/2″ | 1, 16 x 25 x 3/4 | 1, 24 x 25 x 3/4 |
| Lennox ML180UH (Table 1) | D = 24-1/2″ | 16 X 25 X 1 (2) | 24 X 25 X 1 (1) |
| York TM9E (Table 4) | A = 14 1/2″, 1000 CFM | 16 x 25 | 14 x 25 |
| York TM9E | B = 17 1/2″, 1200 CFM | 16 x 25 | 16 x 25 |
| York TM9E | C = 21″, 1600 CFM | 16 x 25 | 20 x 25 |
| York TM9E | C = 21″, 2000 CFM | (2) 16 x 25 | 20 x 25 |
| York TM9E | D = 24 1/2″, 2000 CFM | (2) 16 x 25 | 22 x 25 |
| Trane *UHM (factory filter) | B = 17-1/2″ | 1, 17″ X 25″ X 1″ (side or bottom) | |
| Trane *UHM | C = 21″ | 1, 20″ X 25″ X 1″ | |
| Trane *UHM | D = 24-1/2″ | 1, 24″ X 25″ X 1″ | |
Goodman calls its sizes minimums; 0805C, 1005C and 1205D models serving a cooling unit over 4 tons need two 16 x 25 side filters or a bottom filter. Carrier and Heil footnote that side return filters “may have a different filter size. Measure the filter to obtain the correct size.”
Why is the side filter 16 x 25 on every width while the bottom filter grows?
The side opening does not change with width, while the bottom opening is as wide as the cabinet. Lennox’s dimension drawing shows one side return opening, 14″ by 23″, for all four widths, and Rheem’s (-)801T marks a 23″ x 14″ side cutout; a 16 x 25 filter covers that hole on any cabinet. In Carrier’s 59SC6A dimensions the bottom inlet runs from 12-9/16″ on a 14-3/16″ casing to 23″ on a 24-1/2″ casing, which is why the bottom filter steps from 14 x 25 to 24 x 25.
Airflow sets the limit on that single side filter. York’s TM9E manual says not to exceed 1800 CFM through a single side return and a 16×25 filter, and Carrier’s 59SC6A says airflows over 1800 CFM need a bottom, two-side or bottom-and-side return with a minimum 20″ x 25″ filter. York also caps throwaway filters at 300 feet per minute; the arithmetic below shows what each size can carry.
| Nominal filter | Face area | Max CFM at 300 FPM (throwaway) | Max CFM at 600 FPM (high velocity) | Velocity at 1800 CFM |
|---|---|---|---|---|
| 14 x 25 | 2.43 sq ft | 729 | 1,458 | 741 FPM |
| 16 x 25 | 2.78 sq ft | 833 | 1,667 | 648 FPM |
| 20 x 25 | 3.47 sq ft | 1,042 | 2,083 | 518 FPM |
| 24 x 25 | 4.17 sq ft | 1,250 | 2,500 | 432 FPM |
At 1800 CFM a 16 x 25 runs 648 FPM, above York’s 600 FPM basis, while a 20 x 25 runs 518 FPM, which is why big cabinets move to two filters or a bottom return. Filter resistance at those speeds is in our pages on static pressure and MERV ratings and airflow.
Which brands break the 16 x 25 pattern: Trane 17 x 25, Goodman 14 x 24, York 22 x 25?
Three makers do not follow the Carrier and Lennox layout. Trane’s 18-CD30D1-21-EN installer’s guide ships a factory high velocity filter of 17″ X 25″ X 1″ in its 17-1/2″ B cabinet; some need trimming for side or bottom use. Goodman’s 14″ A cabinet lists a 14 X 24 bottom filter and its 24½” D cabinet a 24 X 24, one inch shorter than everyone else’s 25. York’s TM9E lists 22 x 25 for a D cabinet bottom return.
Two brands give no width table. Rheem’s (-)801T installation instructions say “A filter is not provided with the furnace, but one must be field-supplied and installed,”. Bryant’s 915SA product data sells bottom return racks for 1″ filters by width plus washable 16x25x1 and 24x25x1 packs, but we opened no 915SA installation table. Bryant and Heil are Carrier brands, as our brand ownership table shows, and the Heil N96MSN filter table matches the Carrier 59SC6A table cell for cell.
When does the model number give the wrong filter size?
Whenever the filter does not sit in the furnace’s own return opening. Goodman’s installation manual says filters can go “in either the central return register or a side panel external filter rack,” and adds “Larger filters may be used, filters may also be centrally located.” Carrier sizes the media in its separate filter cabinet by the cabinet’s height, not the furnace.
A slot in the cabinet or a rack bolted to its side follows the maker’s table; a media cabinet takes what its own label says; a ceiling return grille has nothing to do with the furnace model. If a filter in a return grille never darkens, our page on a furnace filter that never gets dirty covers the bypass checks.

How do you measure the slot when the old filter is missing or unlabeled?
Measure the opening, then buy the nominal size that is slightly larger. Trane’s own filter guide says the actual size “might be half an inch smaller than the size you need to buy,” and that a 16 x 25 x 1 furnace filter’s measurements “might be 15.5 x 24.5 x .7.” So a slot that measures about 15-3/4″ by 24-3/4″ takes a nominal 16 x 25. Our HVAC filters guide explains nominal versus actual sizes and depth tolerances, and the arrow goes toward the blower, as our backwards filter page explains.
Where do you get the PDF for your exact model?
Search the series part of the model (GM9S80, 59SC6A, ML180UH, TM9E) plus “installation instructions,” since one manual covers the whole series. Carrier and Heil call the table “Air Filter Selection and Duct Sizing”; Lennox calls it Table 1. Carrier, Bryant and Heil PDFs live on shareddocs.com, York’s on yorknow.com and Trane’s on its elibrary site, and Goodman’s filter search tool asks for the model number.
Frequently asked questions
Can I use a 16x25x4 instead of 16x25x5?
Only if the cabinet is built for that depth. Media filters are sized to their own cabinet, not to the furnace: Carrier’s 59SC6A manual lists its separate filter cabinet media as 16 x 25 x 4-5/16, a depth that matches neither label. Match the depth printed on the cabinet door or old filter so air cannot slip past the edges.
Do furnace filters have to be the exact size?
The face must fit the slot without gaps, but the furnace does not need one exact size. Goodman’s GM9S80 spec sheet says other size filters of equal or greater surface area may be used and that filters may be centrally located. Bigger is acceptable; smaller than the maker’s minimum is not, because face velocity rises.
What are the standard sizes for furnace filters?
The maker tables we read use 14 x 25, 16 x 25, 20 x 25 and 24 x 25 at the furnace, 3/4 or 1 inch deep, with 16 x 25 on the side return. Trane’s filter guide lists 16 x 25 x 1, 20 x 20 x 1, 16 x 20 x 1 and 20 x 25 x 1 as common measurements.
What is the Bryant furnace filter size by model number?
Read characters 12 and 13 of the Bryant model: Bryant’s 915SA product data defines 14 as 14.2″, 17 as 17.5″, 21 as 21.0″ and 24 as 24.5″. Bryant is a Carrier brand; Carrier’s 59SC6A table gives 16 x 25 side filters at all four widths and bottom filters of 14, 16, 20 and 24 by 25 inches. Confirm in your Bryant manual.
What is the Heil furnace filter size by model number?
On a Heil N96MSN, the two digits after the heating size are the width: N96MSN0601716 is a 17-1/2″ cabinet. Its Table 9 calls for one 16 x 25 x 3/4 filter on a side or bottom return at that width, and a 20 x 25 x 3/4 bottom filter on a 21″ cabinet.
How we researched this
On November 14, 2026 we read the installation instructions or spec sheets for Goodman GM9S80 (manual and 8/21 spec sheet), Carrier 59SC6A (06/23), Heil N96MSN, Lennox ML180UH (506816-01), York TM9E, Trane *UHM (18-CD30D1-21-EN) and Rheem (-)801T, plus Bryant 915SA product data and Trane’s filter guide. Table rows are copied from those documents; the velocity table is our arithmetic on nominal face area. We excluded retailer size charts, which cite no maker manual, and added no rows for Amana, Bryant or Rheem because we opened no width-to-size table for them. Other series of the same brand can differ.
Sources
- Goodman. “*M9S80 & *C9S80* Installation Instructions.” https://documents.alpinehomeair.com/product/goodmangm9s8gc9s8installationmanual.pdf. Accessed November 2026.
- Goodman. “GM9S80/GC9S80 Spec Sheet, 8/21.” https://cdn.shopify.com/s/files/1/0794/3104/1346/files/GM9S80_GC9S80_Spec_Sheet.pdf. Accessed November 2026.
- Carrier. “59SC6A Installation Instructions (59SC6A-01SI).” https://www.shareddocs.com/hvac/docs/1009/public/0a/59sc6a-01si.pdf. Accessed November 2026.
- Heil (International Comfort Products). “N96MSN Installation Instructions (N96MSN-02SI).” https://www.shareddocs.com/hvac/docs/1011/Public/09/N96MSN-02SI.pdf. Accessed November 2026.
- Lennox. “ML180UH Installation Instructions (506816-01).” https://www.lennox.com/dA/c7cd7e796f/Lennox_ML180UH_IOM.pdf. Accessed November 2026.
- York (Johnson Controls). “TM9E Series Installation Manual.” https://www.yorknow.com/pub/media/documentation/TM9E_Install.pdf. Accessed November 2026.
- Trane. “Installer’s Guide 18-CD30D1-21-EN.” https://elibrary.tranetechnologies.com/public/residential-hvac/Literature/Installation/18-CD30D1-21-EN_09152023.pdf. Accessed November 2026.
- Rheem. “(-)801T Installation Instructions.” https://resource.gemaire.com/is/content/Watscocom/Gemaire/rheem_r801t_en_ii.pdf. Accessed November 2026.
- Bryant. “915SA Product Data (PDS915SA-13).” https://www.shareddocs.com/hvac/docs/1009/Public/0A/PDS915SA-13.pdf. Accessed November 2026.
- Trane. “Furnace Filter Guide.” https://www.trane.com/residential/en/resources/troubleshooting/gas-furnaces/furnace-filter-guide/. Accessed November 2026.
- Goodman. “Filter Search Tool.” https://www.goodmanmfg.com/support/filter-search-tool. Accessed November 2026.